SOC 2 has no password requirements of its own. The Trust Services Criteria never use the word “password.” A CC6.1 point of focus says authentication requirements are established, documented, and managed. You write those requirements, and the CPA firm tests whether you followed them. For most SaaS teams in 2026, the best base is NIST SP 800-63B-4: at least 15 characters when a password is the only factor, at least 8 when it is part of MFA, no forced character mixes, no scheduled changes, a blocklist check, and limits on failed attempts. Then put SSO and MFA in front of as many tools as you can, so few passwords remain to manage.
TL;DR
- The criteria set no length, complexity, rotation, or lockout number. Your approved policy sets them, and the CPA firm tests what it says.
- A 90-day rotation rule is not required. NIST SP 800-63B-4 says not to force scheduled changes, and to force a change when a password is compromised.
- Length, a blocklist of common and breached passwords, rate limiting, and password managers do more than symbol rules.
- SSO with MFA removes most passwords. Write rules for the ones left: the identity provider, break-glass accounts, tools without SSO, database and admin logins, device logins, and any customer password login.
- For a Type 2 report, show the settings held across the period, not only on the day you exported them.
What do the SOC 2 criteria say about passwords?
The AICPA Trust Services Criteria talk about authentication and credentials, not passwords. These are the points of focus that matter:
| Criterion | Point of focus | What it says |
|---|---|---|
| CC6.1 | Identifies and Authenticates Users | Identify and authenticate people, infrastructure, and software before access, and use stronger methods such as MFA where your risk calls for it |
| CC6.1 | Manages Identification and Authentication | Authentication requirements are established, documented, and managed for people and systems |
| CC6.2 | Creates Access Credentials to Protected Information Assets | Credentials are created only with authorization from the asset owner or an authorized custodian |
| CC6.2 | Prevents the Use of Credentials When No Longer Valid | Disable, destroy, or otherwise block credentials that are no longer valid |
| CC6.6 | Protects Identification and Authentication Credentials | Protect credentials in transit outside the system boundary |
The second row matters most for passwords. It does not say what the rule must be. It says you need a written rule and you need to run it. The same AICPA document says using the criteria “does not require an assessment of whether each point of focus is addressed,” so even these are characteristics to consider, not a checklist.
So guides that state a required length or interval are giving advice, not quoting SOC 2. The criteria leave the choice to you, and your CPA firm judges whether your choice is reasonable for your risk.
Which password rules should you write?
NIST SP 800-63B-4 is written for US federal systems, but it is a widely used public reference for password rules, and it is free to read. Here is how its password section compares with the rules many older policies still carry.
| Setting | Older policy habit | NIST SP 800-63B-4 | A rule a small team can run |
|---|---|---|---|
| Minimum length | 8 characters | 15 for single-factor passwords, 8 when only used with MFA | 15 where a password is the only factor, 12 or more behind MFA |
| Maximum length | Often capped at 16 or 20 | Should allow at least 64 | Allow at least 64 so generated passwords fit |
| Composition | Upper, lower, number, symbol | Shall not impose composition rules | No forced mixes; check against a blocklist instead |
| Blocklist | Rarely written down | Shall compare new passwords to common, expected, and compromised values, and explain a rejection | Turn on breached and common password checks where the tool has them |
| Rotation | Every 60 or 90 days | Shall not require periodic changes; shall force a change on evidence of compromise | Change on suspected compromise, and rotate shared logins when a holder leaves |
| Failed attempts | Lock after 3 to 5 tries | Shall rate limit; no more than 100 consecutive failures before disabling, with growing delays allowed | Use the identity provider’s lockout or throttling, and write it down |
| Hints and questions | Security questions for reset | Shall not allow hints visible before login, or prompt for security questions when a password is chosen | Reset through the identity provider with MFA, never by question |
| Password managers | Paste sometimes blocked | Shall allow password managers and autofill; should allow paste | Issue a company password manager and require it for shared secrets |
The 12-character number for passwords behind MFA is my suggestion, not a NIST rule. NIST allows 8 there. Pick a number that your tools can enforce everywhere, because a rule that one system cannot meet becomes an exception you have to track.
NIST explains why it drops symbol rules: people respond to them in predictable ways, so a required capital and digit tends to turn “password” into “Password1” rather than into something hard to guess.
Two notes on writing the standard:
- Separate the rule from the tool. “Passwords used as the only factor are at least 15 characters” is the rule. “The identity provider’s minimum length is set to 15” is the setting that proves it. Auditors test both.
- Keep “reuse” in the standard. NIST does not set a password history count, but reuse of a company password on a personal service is a common way credentials leak. A rule against reuse plus a password manager handles it.
Does SOC 2 require password rotation?
No. Nothing in the criteria sets a rotation interval, and NIST SP 800-63B-4 says verifiers “SHALL NOT require subscribers to change passwords periodically.”
The catch is your own policy. If your approved policy says “every 90 days,” the CPA firm will sample accounts and check that they changed every 90 days. To drop the rule, approve a dated policy change. The new rule applies from its effective date, and the CPA firm still tests the old rule for the part of the period before it, so a change before the period starts is simplest. Replace the 90-day rule with what NIST does require: a forced change when there is evidence of compromise. Write down what counts as evidence, such as a breach alert from your identity provider, a leaked credential found in a repository, or a lost device that had saved passwords.
Machine credentials are different. API keys, database passwords, and service account secrets are not memorized by a person, so the NIST rule against scheduled changes is about a different problem. Rotate or expire those on a schedule that fits the risk, or replace them with short-lived credentials. The secrets management guide covers inventory, rotation triggers, and leak response for them. The MFA requirements guide covers how service accounts fit an authentication control, and the AI coding agents guide covers agent credentials.
Where do passwords still matter after SSO?
SSO with MFA turns most of your tools into one login. That is the biggest password improvement a small team can make. But some passwords survive it, and these are the ones auditors ask about.
| Login | Why it survives SSO | What the standard should say |
|---|---|---|
| Identity provider account | It is the login SSO depends on | Long password or passkey, MFA (phishing-resistant preferred), reset only through a verified process |
| Cloud root and break-glass accounts | Kept outside SSO for emergencies | Long random password in a restricted vault, MFA, named holders, alert and review on each use |
| Tools without SSO | The plan or product does not support it | Generated password from the password manager, MFA where offered, kept on the non-SSO list |
| Local device and OS logins | The laptop unlock happens before SSO | A memorized device password or passcode, plus the screen lock in your device baseline |
| Database, server, and admin console logins | Some infrastructure has its own local users | Prefer identity-based access; otherwise generated secrets stored in a vault, with an owner |
| Customer logins to your product | Your customers are not on your identity provider | Follows your commitments; document it separately from workforce rules |
Customer logins deserve their own line. SOC 2 does not require any customer password rule, but if your security page, contract, or system description promises one, the report can test it. If your product stores customer passwords, NIST SP 800-63B-4 says to store them salted and hashed with a password hashing scheme that makes each guess expensive. Your secure development process should own that, and your policy templates should not promise more than the product does.
Shared credentials are the last gap. FileGRC’s starter policy allows a shared account only with a documented technical need, a named owner, restricted use, protected credentials, and logging. If two people must use one account, keep it in a shared vault entry in the password manager, limit who can see it, and rotate it when someone with access leaves. The onboarding and offboarding checklist covers that step.
A sample SOC 2 password standard
Here is a short standard a small SaaS team can adapt. Change every number to match what your tools enforce before you approve it.
## Passwords
Scope: workforce and administrative logins to in-scope Systems.
- Use SSO with MFA wherever the System supports it.
- MFA is required for workforce and administrative access to production,
source control, email, identity, and Systems with Confidential or
Restricted data. A password alone never meets this rule.
- Passwords checked by the identity provider or a System as the only
factor: at least 15 characters.
- Passwords used with MFA: at least 12 characters.
- Allow at least 64 characters. No required character mixes.
- Reject common, expected, and breached passwords where the System can check.
- Do not require scheduled changes. Force a change on suspected compromise.
- Throttle or lock after repeated failed attempts: [record the identity
provider's value, and each non-SSO System's own setting].
- No password hints or security questions for recovery. Reset SSO passwords
and factors only through the identity provider after MFA or verified
identity, and log each reset. For root and non-SSO accounts, protect the
recovery email or phone with the same rules and record each recovery.
- Sessions: re-authenticate after [record the idle and maximum session
times] in the identity provider and in each non-SSO System.
- Memorized passwords (device unlock, the password manager's own password,
and the identity provider password): unique, and never written down or
stored elsewhere. The identity provider and password manager passwords meet
the length rules above. Device unlock is a local login, so it follows the
device baseline instead of the 15-character rule: [record the minimum].
- Store all other work passwords only in the company password manager. Do
not reuse them anywhere else. Do not share personal credentials. A shared
account needs a documented technical need, a named owner, restricted use,
a restricted vault entry, and logging, such as the vault's access log.
- Break-glass and root accounts follow the shared-account rule, with random
passwords, MFA, named holders, and an alert and a review on each use.
- Rotate shared, break-glass, and root credentials when anyone with access
leaves, and on suspected compromise.
- Systems that cannot meet this standard need an approved, time-bound
exception with a risk assessment, compensating safeguards, an owner, and a
review or end date.
What evidence shows the password control operated?
A Type 1 report looks at design on one date. A Type 2 report tests whether the control operated through the period, so plan for evidence that covers time.
- The approved standard and the policy it sits under, with an effective date before the period starts.
- Dated exports or screenshots of password settings from the identity provider near the start and end of the period. Include length, lockout, breach checks, and recovery settings.
- Admin or audit logs showing any change to authentication settings during the period, with the change approval. Identity tools often keep logs for a limited time, so export them on a schedule.
- A list of systems outside SSO, with each system’s password and MFA settings. Reconcile it to your system inventory so nothing is missing.
- Password manager evidence: who has access to shared vaults, and proof that departed staff lost access.
- Break-glass use records: each use, who used it, why, and the review after.
- Compromise-driven resets: the alert, the forced change, and the follow-up.
- Approved exceptions, each with scope, owner, compensating safeguards, and an end date.
Your CPA firm picks the samples and decides what it accepts. Ask early which format it wants for settings exports. Access review records belong with the access review evidence guide.
Common gaps auditors find
- The policy says 90-day rotation, but nobody rotates, so the written rule fails on the first sample.
- The policy says 15 characters, but one tool caps passwords at 12 and nobody recorded an exception.
- A cloud root account has no MFA and an old password a former employee knew.
- A tool outside SSO has shared logins stored in chat.
- The identity provider settings changed mid-period with no approval record.
- Settings evidence exists only for the last week of the period.
If one of these becomes an audit exception, the audit exceptions guide explains what it means for the report.
Record the password standard in FileGRC
FileGRC is a Git-native GRC workspace for SOC 2 work. JSON holds
structured records, Markdown holds long-form work, and Git supplies the change
history. A new workspace includes a proposed strong authentication control
(IAM-02) mapped to CC6.1, CC6.2, and CC6.6, and a proposed Information
Security Policy with an “Identification, Authentication, and Password Policy” section.
That section says management documents password length, composition, reuse,
lockout, session, and recovery settings in approved standards or System
procedures. Starter records are proposals, not compliance claims, so edit both
until they match how you run logins.
Check what the control still needs:
npx filegrc get control control-strong-authentication
npx filegrc program-readiness --control control-strong-authentication
On a new workspace, the readiness output asks you to check MFA, unique accounts, default credentials, and admin roles for each tool that touches production, source code, email, identity, or sensitive data. It also asks you to write the procedure in the control’s Record Markdown, record the procedure revision and effective date, and link an Identity and Access evidence source.
Add your password standard as one section of the control’s Markdown file,
data/controls/control-strong-authentication.md, which FileGRC treats as the
control’s procedure. The rest of that file should name who runs the control,
the current identity provider configuration, and the MFA, default-credential,
and admin-role steps. Get the standard approved before the report period
starts, then record its revision and effective date on the control in
procedureRevision and procedureEffectiveOn. Run npm run validate and
review the diff before you commit. Because the standard lives in Git, every
change to the written rule has an author, a date, and a reviewable diff. A
commit and a revision field do not show management approval by themselves, so
keep the approval record, such as the approver’s sign-off on the change, with
the evidence. A
change to the identity provider’s actual settings still needs its own proof:
the provider’s admin log and the approval for the change.
To link your identity provider as the evidence source, follow the same
Component steps shown in the
endpoint security guide, with
evidenceSourceKinds set to ["identity-access"]. If each System’s Record Markdown
notes whether it uses SSO, an agent with access to the repository can read
those notes with the control, its standard, and its exceptions, and flag a
System outside SSO with no recorded settings or a standard that still says 90
days.
Your identity provider, each system, and your password manager enforce the settings. FileGRC does not set passwords, pull settings exports, or decide whether your evidence is enough. Your team writes the standard, configures the tools, and exports the proof. An independent CPA firm performs the SOC 2 examination and judges whether the control was designed and operated well.
Run your SOC 2 program as files in Git.
Keep policies, controls, work, and evidence indexes in a repository your team and agents can inspect. Add optional FileGRC Autopilot email and Slack reminders to keep work moving.
Frequently asked questions
Does SOC 2 have password requirements?
Not specific ones. The AICPA Trust Services Criteria never use the word password. A CC6.1 point of focus says identification and authentication requirements are established, documented, and managed, so you write the password rules for your systems, and the CPA firm tests whether you followed them. Many teams base those rules on NIST SP 800-63B-4.
Does SOC 2 require changing passwords every 90 days?
No. Nothing in the Trust Services Criteria sets a rotation interval. NIST SP 800-63B-4 says verifiers shall not require users to change passwords periodically, and shall force a change when there is evidence of compromise. If your approved policy still says 90 days, the CPA firm will test that rule. To drop it, approve a dated policy change. The new rule applies from its effective date, and the old rule is still tested for the time before it.
What minimum password length should a SOC 2 password policy use?
SOC 2 does not set one. NIST SP 800-63B-4 requires at least 15 characters when a password is the only factor, and allows a minimum of 8 when the password is only used as part of multi-factor authentication. SOC 2 leaves the choice to you. A practical standard is 15 characters for password-only logins, 12 or more behind MFA, and a maximum of at least 64 characters so password managers work.
Do SOC 2 passwords need uppercase letters, numbers, and symbols?
No. SOC 2 does not require composition rules, and NIST SP 800-63B-4 says verifiers shall not impose them. It asks for length, a check against a blocklist of common, expected, and breached passwords, and rate limiting on failed attempts instead. If a tool forces composition rules you cannot turn off, record it as an approved exception to your standard for that tool.
How many failed login attempts before lockout for SOC 2?
SOC 2 does not name a number. NIST SP 800-63B-4 requires rate limiting and caps consecutive failed attempts on one account at no more than 100 before the authenticator is disabled, and it allows delays that grow as failures add up. Pick the setting your identity provider supports, write it into your standard, and keep the settings export as evidence.
If we use SSO with MFA, do password rules still matter for SOC 2?
Yes, but for fewer logins. The identity provider password, break-glass and root accounts, tools without SSO, database and admin console logins, local device logins, and any password login your product offers customers all still need a written rule. SSO shrinks the list, and the control should name what remains.
Does FileGRC enforce password settings?
No. Your identity provider, each system, and your password manager enforce password settings. FileGRC is a Git-native GRC workspace for SOC 2 work. It records the authentication control, your written password standard, the systems it covers, exceptions, and fixed evidence your team exports, with JSON for structured records, Markdown for long-form work, and Git for change history.